Availability: | |
---|---|
Quantity: | |
GW1-12
DGG
◇ Simple structure,beautiful appearance,and convenient installation;
◆ The insulator is made of high-strength porcelain material with a large climbing distance design,which has strong pollution resistance and environmental adaptabiity,and can meet the operational requirements in high-altitude areas;
◆ Equipped with an interlocking device,it can effectively prevent accidental operation ofthe grounding knife;
◇ Easy to operate,reliable to operate,and can be equipped with manual or electric operating mechanisms according to user requirements.
◇ Simple structure,beautiful appearance,and convenient installation;
◆ The insulator is made of high-strength porcelain material with a large climbing distance design,which has strong pollution resistance and environmental adaptabiity,and can meet the operational requirements in high-altitude areas;
◆ Equipped with an interlocking device,it can effectively prevent accidental operation ofthe grounding knife;
◇ Easy to operate,reliable to operate,and can be equipped with manual or electric operating mechanisms according to user requirements.
No. | Project | Unit | Technical parameter | ||||
1 | Rated voltage | kV | 12 | ||||
2 | Rated frequency | Hz | 50 | ||||
3 | Rated current | A | 630 | 1250(1600) | |||
4 | Rated short-term withstand current and duration | Isolation switch | kA/s | 20/4 | 25/4 | 25/4 | 31.5/4 |
Grounding switch | kA/s | 20/2 | 25/2 | 25/2 | 31.5/2 | ||
5 | Rated peak withstand current | kA | 25 | 63 | 63 | 80 | |
6 | Rated short-term power frequency withstand voltage | Phase to phase,phase to ground (dry test) | kV/min | 42/1 | |||
Fracture surface (dry test) | 48/1 | ||||||
Phase to phase,phase to ground (wet test) | 42/1 | ||||||
7 | Rated lightning impulse withstand voltage | Phase to phase,phase to ground | kV | 75 | |||
Fracture surface | 85 | ||||||
8 | Loop resistance | μΩ | ≤100 | ≤80 | |||
9 | Creepage distance | mm | ≤372(E-level anti fouling) | ||||
10 | Mechanical lifespan | Times | 3000Isolation switch/grounding switch | ||||
Note:If the altitude is higher than 1000m,the rated insulation level should be adjusted accordingly. |
No. | Project | Unit | Technical parameter | ||||
1 | Rated voltage | kV | 12 | ||||
2 | Rated frequency | Hz | 50 | ||||
3 | Rated current | A | 630 | 1250(1600) | |||
4 | Rated short-term withstand current and duration | Isolation switch | kA/s | 20/4 | 25/4 | 25/4 | 31.5/4 |
Grounding switch | kA/s | 20/2 | 25/2 | 25/2 | 31.5/2 | ||
5 | Rated peak withstand current | kA | 25 | 63 | 63 | 80 | |
6 | Rated short-term power frequency withstand voltage | Phase to phase,phase to ground (dry test) | kV/min | 42/1 | |||
Fracture surface (dry test) | 48/1 | ||||||
Phase to phase,phase to ground (wet test) | 42/1 | ||||||
7 | Rated lightning impulse withstand voltage | Phase to phase,phase to ground | kV | 75 | |||
Fracture surface | 85 | ||||||
8 | Loop resistance | μΩ | ≤100 | ≤80 | |||
9 | Creepage distance | mm | ≤372(E-level anti fouling) | ||||
10 | Mechanical lifespan | Times | 3000Isolation switch/grounding switch | ||||
Note:If the altitude is higher than 1000m,the rated insulation level should be adjusted accordingly. |
◆ Altitude:not exceeding 1000m.If the altitude is higher than 1000m,the rated insulation level should be adjusted accordingly;
◇ Environmental temperature:upper limit +45℃,lower limit -40℃,hottest month average temperature of 30℃,maximum daily
temperature diference of 25K;
◇ Solar radiation intensity (outdoor):0.1W/cm²;
◇ Wind speed/pressure (outdoor):34m/s (700Pa);
◇ Pollution level:e-level;
◇ Ice thickness:≤10mm;
◇ Humidity:Daily average relative humidity ≤95%,monthly average relative humidity ≤90%;
◇ Earthquake tolerance:horizontal acceleration of 0.3m/s²,vertical acceleration of 0.15 m/s²;
◇ Safety factor:sine resonance three cycle wave,safety factor above 1.67.
◆ Altitude:not exceeding 1000m.If the altitude is higher than 1000m,the rated insulation level should be adjusted accordingly;
◇ Environmental temperature:upper limit +45℃,lower limit -40℃,hottest month average temperature of 30℃,maximum daily
temperature diference of 25K;
◇ Solar radiation intensity (outdoor):0.1W/cm²;
◇ Wind speed/pressure (outdoor):34m/s (700Pa);
◇ Pollution level:e-level;
◇ Ice thickness:≤10mm;
◇ Humidity:Daily average relative humidity ≤95%,monthly average relative humidity ≤90%;
◇ Earthquake tolerance:horizontal acceleration of 0.3m/s²,vertical acceleration of 0.15 m/s²;
◇ Safety factor:sine resonance three cycle wave,safety factor above 1.67.
Outline and Installation Dimension
Model and Meaning
Outline and Installation Dimension
Model and Meaning
◇ Please indicate the product name and model;
◇ Please indicate the rated voltage,rated current,and rated short-term withstand current;
◇ Please indicate whether a grounding switch is required;
◇ Please indicate the anti pollution level;
◇ Please indicate the operating mechanism model,auxiliary switch type,and number of contacts;
◇ Please indicate the order quantity and delivery time.
◇ Please indicate the product name and model;
◇ Please indicate the rated voltage,rated current,and rated short-term withstand current;
◇ Please indicate whether a grounding switch is required;
◇ Please indicate the anti pollution level;
◇ Please indicate the operating mechanism model,auxiliary switch type,and number of contacts;
◇ Please indicate the order quantity and delivery time.