Availability: | |
---|---|
Quantity: | |
JDZW6-10
DGG
The JDZW6-10 Series voltage transformer (hereinafter referred to as the transformer) is suitable for outdoor power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 10kV. It is used for energy metering, voltage monitoring, and relay protection.It is particularly suitable for unmanned and oil-free substations for remote sensing, remote signaling, and remote adjustment.
The upgraded model of voltage transformer is produced and designed by our company, and the specifications and detailed parameters of the product are adjusted according to the customer's parameter requirements to meet the needs of use in different places, such as substations, distribution rooms, transmission lines, or ring main units. Design drawings for indoor and outdoor based on customer requirements.
The JDZW6-10 Series voltage transformer (hereinafter referred to as the transformer) is suitable for outdoor power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 10kV. It is used for energy metering, voltage monitoring, and relay protection.It is particularly suitable for unmanned and oil-free substations for remote sensing, remote signaling, and remote adjustment.
The upgraded model of voltage transformer is produced and designed by our company, and the specifications and detailed parameters of the product are adjusted according to the customer's parameter requirements to meet the needs of use in different places, such as substations, distribution rooms, transmission lines, or ring main units. Design drawings for indoor and outdoor based on customer requirements.
Rated voltage ratio (kV) | Accuracy class | Rated output (VA) | Limit output (VA) |
6/0.1/0.22 | 0.2/3 | 20/500 | 800 |
6/0.22 | 3 | 500 | 800 |
10/0.1/0.22 | 0.2/3 | 30/500 | 800 |
10/0.22 | 3 | 500 | 800 |
Rated voltage ratio (kV) | Accuracy class | Rated output (VA) | Limit output (VA) |
6/0.1/0.22 | 0.2/3 | 20/500 | 800 |
6/0.22 | 3 | 500 | 800 |
10/0.1/0.22 | 0.2/3 | 30/500 | 800 |
10/0.22 | 3 | 500 | 800 |
1. Rated insulation level: 7.2/32/60KV, 12/42/75KV
2. The surface creepage distance meets the second level pollution level.
3. This type of transformer meets the requirements of GB1207-1997 "Voltage Transformers"
4. The partial discharge level complies with GB7354-1987 "Measurement of Partial Discharge in Transformers", and its apparent discharge capacity is not greater than 20PC.
5. Environmental temperature: -30 ℃~40 ℃. The daily average temperature does not exceed 30 ℃
6. Altitude: not exceeding 1000m.
7. Other technical parameters are shown in the table below
1. Rated insulation level: 7.2/32/60KV, 12/42/75KV
2. The surface creepage distance meets the second level pollution level.
3. This type of transformer meets the requirements of GB1207-1997 "Voltage Transformers"
4. The partial discharge level complies with GB7354-1987 "Measurement of Partial Discharge in Transformers", and its apparent discharge capacity is not greater than 20PC.
5. Environmental temperature: -30 ℃~40 ℃. The daily average temperature does not exceed 30 ℃
6. Altitude: not exceeding 1000m.
7. Other technical parameters are shown in the table below