1.The switchgear structure is shown in the following figure.
2.Fully metal modular assembly structure,wide combination scheme.
3.The cabinet is made of aluminum-zinc plate with strong corrosion resistance,processed by CNC high-precision numerical control equipment,using advanced multiple folding technology,connected with rivet nuts and high-strength bolts,&has high precision,corrosion resistance,light weight,high strength,and strong partsversatility.
4.It can be equipped with ZN63A(VS1)-12 series or imported VD4 series vacuum circuit breakers,with wide applicability,high reliability,and long-term maintenance-free.
5.Trolley equipped with working &test positions,&each position has positioning &display devices,which is safe &reliable.
6.Alltypes of trolleysare changed according to the modular building blockstyle to ensure that the same specification trolleyscan be freely interchanged,and different specifications trolleys are absolutely not allowed to enter.
1.The switchgear structure is shown in the following figure.
2.Fully metal modular assembly structure,wide combination scheme.
3.The cabinet is made of aluminum-zinc plate with strong corrosion resistance,processed by CNC high-precision numerical control equipment,using advanced multiple folding technology,connected with rivet nuts and high-strength bolts,&has high precision,corrosion resistance,light weight,high strength,and strong partsversatility.
4.It can be equipped with ZN63A(VS1)-12 series or imported VD4 series vacuum circuit breakers,with wide applicability,high reliability,and long-term maintenance-free.
5.Trolley equipped with working &test positions,&each position has positioning &display devices,which is safe &reliable.
6.Alltypes of trolleysare changed according to the modular building blockstyle to ensure that the same specification trolleyscan be freely interchanged,and different specifications trolleys are absolutely not allowed to enter.
Item | Unit | Data | |
Rated voltage | kV | 3.6/6/7.2/10/11/12/15 | |
Rated frequency | Hz | 50/60 | |
Rated current | A | 630/1250/1600/2000/2500/3150/4000 | |
Rated short-time withstand current(4s) | kA | 16/20/25/31.5/40/50 | |
Rated peak withstand current | kA | 40/50/63/80/100/125 | |
Rated insulation level | 1min power frequency withstand voltage | kV | 42/48 |
Lighting impulse withstand voltage | kV | 75/85 | |
Protection degree | Outer shell IP4X, cubicle, and circuit breaker door open IP2X |
Item | Unit | Data | |
Rated voltage | kV | 3.6/6/7.2/10/11/12/15 | |
Rated frequency | Hz | 50/60 | |
Rated current | A | 630/1250/1600/2000/2500/3150/4000 | |
Rated short-time withstand current(4s) | kA | 16/20/25/31.5/40/50 | |
Rated peak withstand current | kA | 40/50/63/80/100/125 | |
Rated insulation level | 1min power frequency withstand voltage | kV | 42/48 |
Lighting impulse withstand voltage | kV | 75/85 | |
Protection degree | Outer shell IP4X, cubicle, and circuit breaker door open IP2X |
1.Ambient air temperature:maximum temperature +40℃,minimum temperature 15℃;
2.Humidity conditions:
Daily average relative humidity:≤95%;
Daily average water vapor pressure≤2.2kPa;
Monthly average relative humidity:≤90%;
Monthlyaverage water vapor pressures 1.8kPa;
3.Altitude:less than 1000m;
4.Earthquake intensity:not more than 8 degrees
5.The surrounding air should not beobviously polluted by corrosive or flammable gases,water vapor,etc.
6.There is no frequent severe vibration.
7.When used undernormal environmental conditions exceeding the GB3906 specifications,the user and the manufacturer shall negotiate.
1.Ambient air temperature:maximum temperature +40℃,minimum temperature 15℃;
2.Humidity conditions:
Daily average relative humidity:≤95%;
Daily average water vapor pressure≤2.2kPa;
Monthly average relative humidity:≤90%;
Monthlyaverage water vapor pressures 1.8kPa;
3.Altitude:less than 1000m;
4.Earthquake intensity:not more than 8 degrees
5.The surrounding air should not beobviously polluted by corrosive or flammable gases,water vapor,etc.
6.There is no frequent severe vibration.
7.When used undernormal environmental conditions exceeding the GB3906 specifications,the user and the manufacturer shall negotiate.
The following documents and attachments should be provided during supply:
1.Certificate of conformity;
2.Packing list;
3.User manual;
4.Factory inspection report;
5.Relevant electrical drawings;
6.Spareparts specified in the contract;
7.Installation and operation manual for main components.
The following documents and attachments should be provided during supply:
1.Certificate of conformity;
2.Packing list;
3.User manual;
4.Factory inspection report;
5.Relevant electrical drawings;
6.Spareparts specified in the contract;
7.Installation and operation manual for main components.
Ordering Instructions
The following information should be provided when ordering:
1.Main circuit system diagram;
2.Auxiliary circuit electrical schematic diagram,auxiliary circuit voltage;
3.List of components in the cabinet (including component model,name,specification,quantity);
4.Switchgear layout diagram;
5.Cabinet color(if no requirements,supply accordingto our company's standards);
6.List of required spare parts;
7.Other special conditions of use.
Ordering Instructions
The following information should be provided when ordering:
1.Main circuit system diagram;
2.Auxiliary circuit electrical schematic diagram,auxiliary circuit voltage;
3.List of components in the cabinet (including component model,name,specification,quantity);
4.Switchgear layout diagram;
5.Cabinet color(if no requirements,supply accordingto our company's standards);
6.List of required spare parts;
7.Other special conditions of use.