You are here: Home » Products » Circuit Breaker » SF6 Circuit Breaker » LW8-40.5 High Voltage Electric Vacuum SF6 Circuit Breaker for Substations

PRODUCT CATEGORY

Product Detail

loading

Share to:
facebook sharing button
whatsapp sharing button
twitter sharing button
linkedin sharing button
sharethis sharing button

LW8-40.5 High Voltage Electric Vacuum SF6 Circuit Breaker for Substations

LW8-40.5 outdoor high-voltage sulfur hexafluoride circuit breaker (hereinafter referred to as "circuit breaker") is outdoor electrical equipment with three-phase AC 50Hz, which is applicable to the control and protection of 35kV Power Transmission and distribution system and can also be used to connect circuit breakers and switch capacitor banks.

LW8 - 40.5 circuit breaker is equipped with CT T14 spring operating mechanism.

The circuit breaker meets the requirements of GB / T 1984-89 AC high voltage circuit breaker and IEC publication high voltage AC circuit breaker.
 
Availability:
Quantity:

1. The advantages of sulfur hexafluoride sf6 vacuum circuit breakers are numerous. Firstly, they offer superior insulation properties, ensuring a high level of safety during operation...


2. Secondly, these SF6 circuit breakers have a longer lifespan compared to other types, resulting in lower maintenance costs in the long run.


3. Additionally, sulfur hexafluoride sf6 vacuum circuit breakers are more environmentally friendly as they do not contribute to greenhouse gas emissions.


4. Furthermore, the SF6 circuit breakers are highly reliable and efficient in interrupting current flow when necessary. Lastly, these circuit breakers are compact in size, making them suitable for a variety of applications where space is limited..


5. Overall, sulfur hexafluoride SF6 vacuum circuit breakers are a reliable and cost-effective solution for ensuring the safety and efficiency of electrical systems. Their unique combination of insulation properties, longevity, environmental friendliness, reliability, and compact size make them a preferred choice for many industries.


No.

Item

Unit

Data

1

Rated Voltage

kV

40.5

2

Rated Insulation Level

Lightning Impulse Withstand Voltage (Full-wave Peak Value)

185/215 (Fracture)

Power Frequency Withstand Voltage (1 minute)

95

3

Rated Current

A

1600, 2000


4

Mechanical Life

Times

3000


5

SF6 Gas Rated Pressure (gauge pressure at 20oC)

Mpa

0.45


6

Locked Pressure (gauge pressure at 20oC)

Mpa

0.45


7

Minimum Operating Ambient Temperature

oC

-30


8

Rated Short-Circuit Breaking Current

kA

25,  31.5


9

Rated Short-Circuit Closing Current (Peak Value)

63,     80


10

Rated Short-Circuit time Withstand Current (Thermal Stable Current)

25,  31.5

11

Rated Peak Value Withstand Current (Strive to Stabilize the Current)

63,     80

12

Rated Out of Step Breaking Current

63,     80

13

Rated Short-circuit Continuous Time

S

4

14

Closing - Opening Time

Not more than 0.1

15

Opening - Closing Time

Not more than 0.1

16

Rated Operating Order


Open- 0.3s - Close Open - 180s - Close Open

17

Rated Opening and Closing Current of Single Capacitor Bank

A

400

18

Under Rated Short-Circuit Breaking Current's Cumulative Breaking Times  

Times

15,   10

19

Annual Leakage Gas

% year

Not more than 1

20

SF6 Gas Moisture content (20oC)

PPm (V)

Not more than 50

21

Rated Operating Voltage of CT14 Spring Operating Mechanism

V

220V


Closing Coil, Opening Coil Voltage

AC220, DC110, 220


Voltage of Energy Storage Motor

AC220,  DC220


22

SF6 Gas Weight

Kg

8

23

Circuit Breaker (Including Operating Mechanism) Weight

1400

Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.


USAGE: ENVIRONMENTAL CONDITION

1. Altitude: ≤ 1000m, If the altitude is higher than 1000m, the rated insulation level shall be corrected accordingly.

2. Ambient temperature: -40 oC ~ +45 oC,

3. Maximum daily temperature difference: 25 K

4. Humidity: Average daily relative humidity: 95%, average monthly relative humidity: 90%.

5. Sunshine intensity: not more than 0.1W/cm 2

6. Wind Speed: 34m/s

7. Wind pressure: 700Pa

8. Pollution level: e - level

9. Icing thickness: Not more than 10mm

10. Resistance to floor drain: horizontal acceleration 0.3g, vertical acceleration 0.2g