Please Choose Your Language
You are here: Home » Products » Power Transmission Line Equipment » Surge Arrester » Composite Jacket Silicon Rubber Single Phase Lightning/Surge Arrester

PRODUCT CATEGORY

Product Detail

loading

Share to:
facebook sharing button
whatsapp sharing button
twitter sharing button
linkedin sharing button
sharethis sharing button

Composite Jacket Silicon Rubber Single Phase Lightning/Surge Arrester

Lightning arrester is the foundation of insulation coordination for various electrical equipment in the power system,such as transformers,reactors,capacitors,generators,motors,PT,CT,circuit breakers,contactors,etc.The protection performance of ightning arrester determines the internal and externalinsulation indicators of all electrical equipment in the power system,such as short-term power frequency withstand voltage,lightning impulse withstand voltage,and operating impulse withstand voltage.
Metal oxide lightning arrester,commonly known as "zinc oxide lightning arrester,is a new generation of lightning arrester that was widely promoted internationally in the 1980s by countries such as the United States and Japan.It is the most advanced product among conventional lightning arresters.Since the mid-1980s,China has full introduced thistechnology.Through years of practice and digestion,the performance of AC lightning arresters from various professional lightning arrester factories is currently on par with the most advanced products from countries such as the United States,Japan,and Western Europe.Products that truly meet all the requirements of national standards can also meet the requirements of international IEC standards.
The core working componentsof this productare made of multi-element metal oxide powder mainly composed of zinc oxide,which has excellent nonlinear volt ampere characteristics,fast steep wave response,and large current capacity.The products with gaps adopt self blowing gaps and a uniform pressure irradiation structure,which reduces the dispersion of discharge and has a small impact coefficient.
The adoption of composite insulation jackets conforms to the development trend of miniaturization,safety,and maintenance free international power products.Compared with traditional inorganic materials such as ceramics and glass,polymer organic composite materials have the advantages of small olume,light weight,resistance to polltion,cleaning,explosion and vibration, and are the preferred lightning protection components in integrated and modular medium and high voltage transmission and transformation equipment.
 
Availability:
Quantity:
  • YH Series

  • DGG

This product is used in AC 220KV and below power generation,transmission,transformation,and distribution systems.It is used to limit the amplitude of lightning and internal operating overvoltage to the specified level,and is the basic equipment for insulation coordination of the entire system.Meanwhile,this product cannot be used to limit resonance over voltage,and other methods need to be used for system harmonic elimination.

This product model is formulated in accordance with the provisions of JB/T 8459-2006"Method for Formulating Product Models of Thunder Arresters",and gapless products are formulated in accordance with the standard GB 11032-2000 "Metal Oxide Lightning Arresters without Gaps for AC";Products with gaps shall comply with the JB/T 9672-2005 standard for metal oxide surge arresters with series gaps.For important parameters and configuration methods that are not clearly defined in the above standards,they shall be revised and executed in accordance with the requirements of DLT620-1997 "Overvoltage Protection and Insulation Coordination of AC Electrical Equipment".



Low
pressure

Distribution
type

System
nominal
voltage
(kV)
Effective
value

National
standard
model of
lightning
arrester

Rated
voltage
of
lightning
arrester
(kV)
Effective
value
Gapless lightning arrester Gap lightning arrester Residual pressure(kV)
(Peak value)Not less than

2000μs
square
wave
current
capacity
 (A)

4/10
high
current
tolerance
(kA)

Continuous
operating
voltage of
lightning
arrester
 (kV)
Effective
 value

DC 1mA
reference
voltage
(kV)
Not less
than

Maximum
leakage  at
0.75 times
DC
reference
yoltage
(μA)

Power
frequency
discharge
voltage
(kV)
Effective
value
Notless
than
1.2/50
impulse
discharge
voltage
(kV)
Peak
value
Notless
than

Maximum
conductive
current
(μA)

Under
lightning
impulse
current
on 8/20
Unde
30/60
operating
impulse
current

Under
1/4
steep
Wave
impulse
current
Low
pressure
Distribution
type
0.22 YH1.5W-0.28/1.3 0.28 0.24 0.6 50

1.3

75 25
0.38 YH1.5W-0.5/2.6 0.5 0.42 1.2 50


2.6

75 25
Motor
type
0.66* YH2.5WD-1.3/3.6 1.3 0.95 1.8 50

3.6 200 40
1.14* YH2.5WD-2.6/7.2 2.6 1.9 3.6 50 7.2 200 40
3kV Distribution
type
3 YH5WS-3.8/15 3.8 2.0 7.5 50

15.0 12.8 17.3 75 40
3 YH5WS-5/15 5 4.0 7.5 50
- 15.0 12.8 17.3 75 40
3 YH5CS-3.8/13.5 3.8 9.0 13.5 20 13.5 11.4 15.0 75 40
Power
station
type
3 YH5WZ-3.8/13.5 3.8 2.0 7.2 50
13.5 11.5 15.5 200 65
3 YH5WZ-5/13.5 5 4.0 7.2 50
13.5 11.5 15.5 200 65
3 YH5CZ-3.8/12.0 3.8
8.0 12.0 20 12.0 10.2 13.5 200 65
Capacitive
type
3 YH5WR-3.8/13.5 3.8 2.0 7.2 50
13.5 10.5
400 65
3 YH5WR-5/13.5 5 4.0 7.2 50
13.5 10.5 400 65
3 YH5CR-3.8/12.0 3.8 8.0 12.0 20 12.0 9.6 400 65
Generator
type
3.15* YH5WD-3.8/9.5 3.8 2.0 5.7 50


9.5 7.6 10.7 400 65
3.15* YH5WD-4/9.5 4 3.15 5.7 50 9.5 7.6 10.7 400 65
3.15* YH5CD-3.8/8.6 3.8


7.5 8.6 20 8.6 6.9 9.8 400 65
Electric
motor
type
3.15* YH2.5WD-3.8/9.5 3.8 2.0 5.7 50

9.5 7.6 10.7 200 65
3.15* YH2.5WD-4/9.5 4 3.15 5.7 50 9.5 7.6 10.7 200 65
3.15* YH2.5CD-3.8/8.6 3.8


7.5 8.6 20 8.6 6.9 9.8 200 65
Neutral
point type
3.15* YH1.5W-2.4/6 2.4 1.9 3.4 50
6.0 5.0 200 65

Low
pressure

Distribuion
type

System
nomina
voltage
(kV)
Effective
value

National
standard
model of
lightning
arrester

Rated
voltage
of
lightning
arrester
(kV)
Effective
value
Gapless lightning arrester Gap lightning arrester Residual pressure (kV)
(Peak value)Not less than

2000μs
square
wave
current
capacity
(A)

4/10
high
current
tolerance
(kA)
ContinuouS
operating
voltage of
lightning
arrester
 (kV)
Effective
value

DC 1mA
eference
voltage
(kV)
Not less
than

Maximum
eakage at
0.75 times
 DC
reference
voltage
(μA)
Power
freguency
discharge
voltage
(kV)
Effective
value
Not less
than
1.2/50
impulse
discharge
voltage
(kV)
Peak
value
Not less
than
Maximum
conductive
Current
(pA)
Under
lghtning
impulse
current
on8/20

Under
30/60
operating
impulse
current

Under
1/4
steep
wave
impulse
current
6kV Distribution
type
6 YH5WS-7.6/30 7.6 4.0 15.0 50


30.0 25.6 34.6 75 40
6 YH5WS-10/30 10 8.0 15.0 50

30.0 25.6 34.6 75 40
6 YH5CS-7.6/27 7.6

16.0 27.0 20 27.0 22.5 30.0 75 40
Power
station
type
6 YH5WZ-7.6/27 7.6 4.0 14.4 50


27.0 23.0 31.0 200 65
6 YH5WZ-10/27 10 8.0 14.4 50

27.0 23.0 31.0 200 65
6 YH5CZ-7.6/24 7.6


16.0 24.0 20 24.0 20.4 27.0 200 65
Capacitive
type
6 YH5WR-7.6/27 7.6 4.0 14.4 50


27.0 21.0 400 65
6 YH5WR-10/27 10 8.0 14.4 50

27.0 21.0 400 65
6 YH5CR-7.6/24 7.6
16.0 24.0 20 24.0 19.5 400 65
Generator
type
6.3* YH5WD-7.6/18.7 7.6 4.0 11.2 50

18.7 15.0 21.0 400 65
6.3* YH5WD-8/18.7 8 6.3 11.2 50

18.7 15.0 21.0 400 65
6.3* YH5CD-7.6/17 7.6 15.0 17.0 20 17.0 13.8 19.6 400 65
Electric
motor
type
6.3* YH2.5WD-7.6/18.7 7.6 4.0 11.2 50


18.7 15.0 21.0 200 65
6.3* YH2.5WD-8/18.7 8 6.3 11.2 50 18.7 15.0 21.0 200 65
6.3* YH2.5CD-7.6/17 7.6
15.0 17.0 20 17.0 13.8 19.6 200 65
Neutral
point  type
6.3* YH1.5W-4.8/12 4.8 3.8 6.8 50

12.0 10.0 200 65
10kV Distribution
type
10 YH5WS-12.7/50 12.7 6.6 25 50

50 42.5 57.5 75 40
10 YH5WS-17/50 17 13.6 25 50 50 42.5 57.5 75 40
10 YH5CS-12.7/45 12.7
26.0 45 20 45 38.4 51.0 75 40
Power
station
type
10 YH5WZ-12.7/45 12.7 6.6 24 50

45 38.3 51.8 200 65
10 YH5WZ-17/45 17 13.6 24 50

45 38.3 51.8 200 65
10 YH5CZ-12.7/41 12.7
26.0 41 20 41 35.0 46.0 200 65
Capacitive
type
10 YH5WR-12.7/46 12.7 6.6 24 50


46 35.0 400 65
10 YH5WR-17/46 17 13.6 24 50 46 35.0 400 65
10 YH5CR-12.7/41 12.7


26.0 41 20 41 33.0 400 65
Generator
type
10.5* YH5WD-12.7/31 12.7 6.6 18.6 50


31 25 34.7 400 65
10.5* YH5WD-13.5/31 13.5 10.5 18.6 50

31 25 34.7 400 65
10.5* YH5CD-12.7/28 12.7


25.0 28.0 20 28 22.5 32.0 400 65
13.8* YH5WD-17.5/40 17.5 13.8 24.4 50


40.0 32.0 44.8 400 65
15.75* YH5WD-20/45 20.0 15.75 28.0 50

45.0 36.0 50.4 400 65
18.0* YH5WD-23/51 23.0 18.0 31.9 50


51.0 40.8 57.2 400 65
20.0* YH5WD-25/56.2 25.0 20.0 35.4 50


56.2 45.0 62.9 400 65
Electric
motor
type
10.5* YH2.5WD-12.7/31 12.7 6.6 18.6 50


31 25 34.7 200 65
10.5* YH2.5WD-13.5/31 13.5 10.5 18.6 50

31 25 34.7 200 65
10.5* YH2.5CD-12.7/28 12.7 25.0 28.0 20 28 22.5 32.0 200 65
Neutral
point
type
10.5* YH1.5W-8/191.3 8 6.4 11.4 50


19.0 15.9
400 65
13.8* YH1.5W-10.5/23 10.5 8.4 14.9 50


23.0 19.2 400 65
15.75* YH1.5W-12/26 12 9.6 17.0 50


26.0 21.6 400 65
18.0* YH1.5W-13.7/29.2 13.7 11.0 19.5 50


29.2 24.3 400 65
20.0* YH1.5W-15.2/31.7 15.2 12.2 21.6 50

31.7 26.4 400 65

Low
pressure

Distribution
 type

System
nominal
voltage
(kV)
Effective
value

National
standard
model of
lightning
arrester

Rated
voltage
of
lightning
arrester
(kV)
Effective
value
Gapless lightning arrester Gap lightning arrester Residual pressure(kV
(Peak value)Not less than

2000μs
square
wave
current
capacity
(A)

4/10
high
current
tolerance
(kA)
Continuous
operating
voltage of
lightning
arrester
 (kV)
Effective
 value
DC 1mA
reference
voltage
(kV)
Not less
than

Maximum
leakage at
0.75 times
DC
reference
voltage
(μA)
Powe
frequency
discharge
voltage
(kV)
Effective
value
Not less
than
1.2/50
impulse
discharge
voltage
(kV)
Peak
value
Not less
than
Maximum
conductive
current
(μA)

Under
ightning
impulse
current
on 8/20
Unde
30/60
operating
impulse
current

Under
1/4
steep
wave
impulse
current
35kV Power
station
 type
35 YH5WZ-51/134 51 40.8 73 50


134 114 154 400 65
35 YH5WZ-42/134 42 23.4 73 50

134 114 154 400 65
35 YH5CZ-42/124 42


80.0 124 20 124 100 143 400 65
Capacitive
 type
35 YH5WR-51/134 51 40.8 73 50


134 105
400 65
35 YH5WR-42/134 42 23.4 73 50

134 105 400 65
35 YH5CR-42/124 42


80.0 124 20 124 100 400 65
Line
 type
35 YH5WX-51/134 51 40.8 73 50


134 114 154 400 65
35 YH5WX-54/150 54 43.2 77 50

150 128 169 400 65
35 YH5CX-42/120 42
80.0 120 20 120 100 138 400 65
35 YH5CX-42/150 42

80.0 150 20 150 128 169 400 65
Neutral
point  type
35 YH1.5W-30/80 30 24 44 50

80 67.5 400 65
66kV Power
station
 type
66 YH5WZ-84/221 84 67.2 121 50

221 188 254 600 65
66 YH5WZ-90/235 90 72.5 130 50


235 201 270 600 65
66 YH10WZ-84/221 84 67.2 121 50


221 188 248 600 100
66 YH10WZ-90/235 90 72.5 130 50

235 201 264 600 100
Line
type
66 YH5WX-96/250 96 75 140 50

250 213 288 600 65
66 YH5WX-96/275 96 75 154 50


275 234 316 600 65
110kV Power
station
type
110 YH5WZ-100/260 100 78 145 50

260 221 299 600 65
110 YH5WZ-102/266 102 79.6 148 50


266 226 305 600 65
110 YH5WZ-108/281 108 84 157 50


281 239 323 600 65
110 YH10WZ-100/260 100 78 145 50

260 221 291 600 100
110 YH10WZ-102/266 102 79.6 148 50

266 226 297 600 100
110 YH10WZ-108/281 108 84 157 50


281 239 315 600 100
Line
type
110 YH5WX-108/281 108 84 157 50

281 239 323 600 65
110 YH5WX-108/309 108 84 173 50

309 263 348 600 65
110 YH10WX-108/281 108 84 157 50

281 239 315 600 100
110 YH10WX-108/309 108 84 173 50


309 263 348 600 100
110 YH5CX-90/260 90 130 50 170* 525*
260 292 600 65
110 YH10CX-90/260 90 130 50 170* 525*
260
292 600 100
110 YH10CX-96/280 96 140 50 170* 525*
280 314 600 100
110 YH10CX-102/296 102 148 50 170* 525*
296 332 600 100
Neutral
point type
110 YH1.5W-60/144 60 48 85 50


144 135 400 65
110 YH1.5W-72/186 72 58 103 50


186 174 400 65
220kV Power
station
type
220 YH10WZ-192/500 192 150 280 50

500 426 560 800 100
220 YH10WZ-200/520 200 156 290 50

520 442 582 800 100
220 YH10WZ-204/532 204 159 296 50


532 452 594 800 100
220 YH10WZ-216/562 216 168.5 314 50


562 478 630 800 100
Line
type
220 YH10WX-216/562 216 168 314 50

562 478 630 600 100
220 YH10WX-216/618 216 168 346 50


618 526 693 600 100
220 YH10CX-185/520 180
260 50 340* 900*
520
584 600 100
220 YH10CX-192/560 192 280 50 340* 900*
560 628 600 100
220 YH10CX-204/592 204 296 50 340* 900*
592 664 600 100
Neutral
point  type
220 YH1.5W-144/320 144 116 205 50


320 299
600 65
27.5kV Railway
type
27.5 YH5WT-42/120 42 34 65 50

120 98 138 400 65
55kV 55 YH5WT-84/240 84 68 130 50

240 276 276 400 65


◇ The normal usage conditions for conventional products are as follows:

(1)Environmental temperature:not higher than +40℃and not lower than -40℃;

(2)Altitude:not exceeding 3000m;

(3)Power frequency:50±2Hz;60±2Hz;

(4)Maximum wind speed:35m/s;

(5)Free cleaning conditions:areas with moderate pollution and below;

(6)For seamless products,the long-term application of power frequency voltage shall not exceed the continuous operating voltage of the shelter;

(7)For products with gaps,the short-term increase in power frequency voltage at the installation point shall ot exceed the rated voltage of the lightning arrester.

◇ Lightning arresters need to be specially made for long-term use under the following abnormal conditions,and should be specified when ordering:

(1)Temperature or altitude exceeding thestandard(such as in high-altitude,tropical,cold regions,fully enclosed cabinets,near electric furnaces,etc.);

(2)The usage environment contains severe moisture or corrosive gas impurties (such aswater,saltfields,chemical plants,etc.);

(3)Strong ultraviolet radiation (such as in high-altitude,dryand early areaswith strong sunlight,etc.);

(4)Extremely polluted areas (such as mining working faces,construction site working faces,etc.).


The model definition of this product fully complies with the provisions of JB/T 8459-2006"Method for Compiling Lightning Arrester Product Models".The specific model description is as follows:

屏幕截图 2024-09-18 150425

Previous: 
Next: 
Tel: +86-57757576678
Phone/WhatsApp: +8613706870299

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US NOW!
Copyright    2024  Denggao Electric Co., Ltd.  All Rights Reserved.