1. combined instrument transformer offer high accuracy in measuring both voltage and current simultaneously, providing precise data for analysis and control purposes. This ensures that the electrical system operates efficiently and safely. .
2. these combined instrument transformer are compact in size, making them easy to install and integrate into existing systems without taking up too much space. This is particularly beneficial in situations where space is limited or where multiple transformers need to be installed in a confined area. .
3. combined instrument transformer are cost-effective as they eliminate the need for separate voltage and current transformers. This not only reduces the overall cost of the system but also simplifies the installation process, saving time and effort.
4. combined instrument transformers are highly reliable and durable, ensuring long-term performance and minimal maintenance requirements. This makes them a practical and efficient solution for various industrial and commercial applications where accurate measurement of voltage and current is essential for optimal performance.
5. In conclusion, the combination transformers for voltage and current offer a range of benefits that make them a valuable asset in electrical systems..
1. combined instrument transformer offer high accuracy in measuring both voltage and current simultaneously, providing precise data for analysis and control purposes. This ensures that the electrical system operates efficiently and safely. .
2. these combined instrument transformer are compact in size, making them easy to install and integrate into existing systems without taking up too much space. This is particularly beneficial in situations where space is limited or where multiple transformers need to be installed in a confined area. .
3. combined instrument transformer are cost-effective as they eliminate the need for separate voltage and current transformers. This not only reduces the overall cost of the system but also simplifies the installation process, saving time and effort.
4. combined instrument transformers are highly reliable and durable, ensuring long-term performance and minimal maintenance requirements. This makes them a practical and efficient solution for various industrial and commercial applications where accurate measurement of voltage and current is essential for optimal performance.
5. In conclusion, the combination transformers for voltage and current offer a range of benefits that make them a valuable asset in electrical systems..
1. Insulation level:12/42/75kV, 7.2/30/60kV
2. Power factor:cosφ=0.8
3. Rated frequency: 50Hz or 60Hz
4. Weight: 85kg
1. Insulation level:12/42/75kV, 7.2/30/60kV
2. Power factor:cosφ=0.8
3. Rated frequency: 50Hz or 60Hz
4. Weight: 85kg
Current part of the technical parameter | ||||
TYPE | Rated primary current(A) | Accuracy class | Rated output | Insulation level(kV) |
6W | 5-600 | 0.2S-10 | 72|1n | 180|1n |
10W | 5-600 | 0.2S-10 | 72|1n | 180|1n |
Voltage part of the technical parameter | ||||
TYPE | Rated voltage ratio(V) | Accuracy class-rated output(VA) | Limit output | |
6W | 6000/100 | 0.2-15 | 300 | |
10W | 10000/100 | 0.2-15 | 300 | |
Current part of the technical parameter | ||||
TYPE | Rated primary current(A) | Accuracy class | Rated output | Insulation level(kV) |
6W | 5-600 | 0.2S-10 | 72|1n | 180|1n |
10W | 5-600 | 0.2S-10 | 72|1n | 180|1n |
Voltage part of the technical parameter | ||||
TYPE | Rated voltage ratio(V) | Accuracy class-rated output(VA) | Limit output | |
6W | 6000/100 | 0.2-15 | 300 | |
10W | 10000/100 | 0.2-15 | 300 | |
1. Altitude: should not exceed 3500m
2. Ambient temperature:-40ºC~+40ºC
3. Air relative humidity:≤85%
4. Air relative site: outdoor.
1. Altitude: should not exceed 3500m
2. Ambient temperature:-40ºC~+40ºC
3. Air relative humidity:≤85%
4. Air relative site: outdoor.