JLSZV-6W
DGG
The design features of combined transformers include oil-free, miniaturized, high reliability, and maintenance free. For example, the JLSZ-10 high-voltage combination transformer adopts epoxy resin insulation and high-voltage epoxy resin fully enclosed vacuum casting, which improves the insulation performance and safety of the equipment. In addition, the secondary wires and cables of the combined transformer are connected using lead sealed junction boxes, which have anti-theft functions and are also convenient for on-site verification.
The design features of combined transformers include oil-free, miniaturized, high reliability, and maintenance free. For example, the JLSZ-10 high-voltage combination transformer adopts epoxy resin insulation and high-voltage epoxy resin fully enclosed vacuum casting, which improves the insulation performance and safety of the equipment. In addition, the secondary wires and cables of the combined transformer are connected using lead sealed junction boxes, which have anti-theft functions and are also convenient for on-site verification.
◇ Current part of the technical parameters | ||||||
Type | Rated primary current(A) | Correct level/ Rated output(VA) | Short-time thermal current(kA/S) | Rated dynamic stability current (kA) | ||
JLSZV-6W | 5-600 | 0.2S-10 | 7211n | 18011n | ||
JLSZV-10W | 5-600 | 0.2S-10 | 7211n | 180I1n | ||
◇ Voltage part of the technical parameters | ||||||
Type | Rated voltage ratio (V) | Correct level/Rated output (VA) | Limit output (VA) | |||
JLSZV-6W | 6000/100 | 0.2-15 | 300 | |||
JLSZV-10W | 10000/100 | 0.2-15 | 300 |
◇ Current part of the technical parameters | ||||||
Type | Rated primary current(A) | Correct level/ Rated output(VA) | Short-time thermal current(kA/S) | Rated dynamic stability current (kA) | ||
JLSZV-6W | 5-600 | 0.2S-10 | 7211n | 18011n | ||
JLSZV-10W | 5-600 | 0.2S-10 | 7211n | 180I1n | ||
◇ Voltage part of the technical parameters | ||||||
Type | Rated voltage ratio (V) | Correct level/Rated output (VA) | Limit output (VA) | |||
JLSZV-6W | 6000/100 | 0.2-15 | 300 | |||
JLSZV-10W | 10000/100 | 0.2-15 | 300 |
Combined transformers include various types such as ordinary current transformers, through type current transformers, multi tap current transformers, and current transformers with different transformation ratios. A regular current transformer consists of a primary winding, a secondary winding, an iron core and frame, a housing, wiring terminals, etc. Its working principle is similar to that of a transformer. A through type current transformer does not have a primary winding, and generates magnetic flux through a wire passing through the iron core, thereby generating a secondary current. Multi tap current transformers obtain multiple different transformation ratios by adding multiple taps to meet the demands of different load currents. Current transformers with different transformation ratios provide multiple independent windings to meet the needs of different transformation ratios and accuracy levels.
Combined transformers include various types such as ordinary current transformers, through type current transformers, multi tap current transformers, and current transformers with different transformation ratios. A regular current transformer consists of a primary winding, a secondary winding, an iron core and frame, a housing, wiring terminals, etc. Its working principle is similar to that of a transformer. A through type current transformer does not have a primary winding, and generates magnetic flux through a wire passing through the iron core, thereby generating a secondary current. Multi tap current transformers obtain multiple different transformation ratios by adding multiple taps to meet the demands of different load currents. Current transformers with different transformation ratios provide multiple independent windings to meet the needs of different transformation ratios and accuracy levels.
Combined transformers are widely used in energy metering, measurement, and protection in power systems. For example, in 10kV power lines and branch lines, combined transformers are used for line loss assessment and for measuring electrical energy on the high-voltage side branch lines of power transformers. In addition, there is a specially designed high-voltage metering box (combined transformer), which is mainly composed of a combined transformer and an electricity meter box. It has the advantages of high measurement accuracy, light weight, easy installation, and anti electricity theft.
Combined transformers are widely used in energy metering, measurement, and protection in power systems. For example, in 10kV power lines and branch lines, combined transformers are used for line loss assessment and for measuring electrical energy on the high-voltage side branch lines of power transformers. In addition, there is a specially designed high-voltage metering box (combined transformer), which is mainly composed of a combined transformer and an electricity meter box. It has the advantages of high measurement accuracy, light weight, easy installation, and anti electricity theft.