Availability: | |
---|---|
Quantity: | |
1. LZZBJ9 Type Electric current transformers are essential components in electrical systems, providing accurate measurements of current flow.
2. This type current transformer key advantage lies in their ability to safely and efficiently transform high currents into manageable levels for measurement and control purposes.
3. The current transformer offer high levels of safety by isolating the measurement circuit from the high voltage circuit.
4. These instrument current transformer compact in size, making them easy to install and maintain. Furthermore, they have a wide operating range, allowing them to be used in various applications.
5. The current transformer are cost-effective solutions for current measurement, offering long-term reliability and efficiency.
6. electric current transformers,split core current transformer,instrument current-transformer and so on all play a crucial role in ensuring the smooth operation of electrical systems.
1. LZZBJ9 Type Electric current transformers are essential components in electrical systems, providing accurate measurements of current flow.
2. This type current transformer key advantage lies in their ability to safely and efficiently transform high currents into manageable levels for measurement and control purposes.
3. The current transformer offer high levels of safety by isolating the measurement circuit from the high voltage circuit.
4. These instrument current transformer compact in size, making them easy to install and maintain. Furthermore, they have a wide operating range, allowing them to be used in various applications.
5. The current transformer are cost-effective solutions for current measurement, offering long-term reliability and efficiency.
6. electric current transformers,split core current transformer,instrument current-transformer and so on all play a crucial role in ensuring the smooth operation of electrical systems.
1..Insulation level:12/42/75kV
2.Power factor:cosφ=0.8(lag)
3. Rated secondary current: 5A or 1A
4.Rated frequency :50Hz or 60Hz
5.Ambient temperature:-5ºC~+40ºC
6.Weight: 13kg
1..Insulation level:12/42/75kV
2.Power factor:cosφ=0.8(lag)
3. Rated secondary current: 5A or 1A
4.Rated frequency :50Hz or 60Hz
5.Ambient temperature:-5ºC~+40ºC
6.Weight: 13kg
| Accuracy class | Rated output | Rated short-time | Rated Insulation |
5 | 0.2S | 10 | 0.36 | 0.9 |
10 | 0.72 | 1.8 | ||
15 | 1.08 | 2.7 | ||
20 | 1.44 | 3.6 | ||
25 | 1.8 | 4.5 | ||
30 | 2.16 | 5.4 | ||
40 | 2.88 | 6.3 | ||
50 | 3.6 | 7.2 | ||
60 | 4.32 | 8.1 | ||
75 | 5.4 | 13.5 | ||
80 | 5.76 | 14.4 | ||
100 | 7.2 | 18 | ||
120 | 8.64 | 21.6 | ||
150 | 10.8 | 27 | ||
200 | 14.4 | 36 | ||
250 | 18 | 45 | ||
300 | 21.6 | 54 | ||
400 | 28.8 | 63 | ||
500 | 36 | 72 | ||
600 | 43.2 | 108 |
| Accuracy class | Rated output | Rated short-time | Rated Insulation |
5 | 0.2S | 10 | 0.36 | 0.9 |
10 | 0.72 | 1.8 | ||
15 | 1.08 | 2.7 | ||
20 | 1.44 | 3.6 | ||
25 | 1.8 | 4.5 | ||
30 | 2.16 | 5.4 | ||
40 | 2.88 | 6.3 | ||
50 | 3.6 | 7.2 | ||
60 | 4.32 | 8.1 | ||
75 | 5.4 | 13.5 | ||
80 | 5.76 | 14.4 | ||
100 | 7.2 | 18 | ||
120 | 8.64 | 21.6 | ||
150 | 10.8 | 27 | ||
200 | 14.4 | 36 | ||
250 | 18 | 45 | ||
300 | 21.6 | 54 | ||
400 | 28.8 | 63 | ||
500 | 36 | 72 | ||
600 | 43.2 | 108 |