◇ There is an obvious disconection point that has the function of an isolation switch,creating asafe working environment for maintenance lines and equipment,and increasing the safety of maintenance personnel;
◆ Simple structure,high cost-effectiveness,easy operation,and easy maintenance;
◇ Strong adapt ability to outdoor environments;
◇ Large climbing distance design to meet the operational requirements in high-altitude areas.
◇ There is an obvious disconection point that has the function of an isolation switch,creating asafe working environment for maintenance lines and equipment,and increasing the safety of maintenance personnel;
◆ Simple structure,high cost-effectiveness,easy operation,and easy maintenance;
◇ Strong adapt ability to outdoor environments;
◇ Large climbing distance design to meet the operational requirements in high-altitude areas.
No. | Name | Unit | Data | ||
1 | Rated frequency | Hz | 50 | ||
2 | Rated voltage | kV | 40.5 | ||
3 | Rated current of the same family of fuse components | A | 100 | 200 | |
4 | Rated breaking current | kA | 6 | 8 | |
5 | Rated short-term power frequency voltage | To the ground | kV/min | 95/1 | |
Fracture | 2018/1 | ||||
6 | Lightning impulse withstand | To the ground | kV | 185 | |
Voltage | 215 | ||||
7 | Creepage distance | mm | >1256 | ||
8 | Mechanical lifespan | Times | 300 |
No. | Name | Unit | Data | ||
1 | Rated frequency | Hz | 50 | ||
2 | Rated voltage | kV | 40.5 | ||
3 | Rated current of the same family of fuse components | A | 100 | 200 | |
4 | Rated breaking current | kA | 6 | 8 | |
5 | Rated short-term power frequency voltage | To the ground | kV/min | 95/1 | |
Fracture | 2018/1 | ||||
6 | Lightning impulse withstand | To the ground | kV | 185 | |
Voltage | 215 | ||||
7 | Creepage distance | mm | >1256 | ||
8 | Mechanical lifespan | Times | 300 |
◆ Altitude:not exceeding 4000m;
◆ The ambient temperature shall not be higher than+40℃ and not lower than -40℃;
◆ The product is not suitable for the following places:
1)Places with combustion or explosion hazards;
2)Places with severe vibration or impact;
3)Areas with conductive and chemical gas effects,as well as severe contamination and salt spray.
◆ Altitude:not exceeding 4000m;
◆ The ambient temperature shall not be higher than+40℃ and not lower than -40℃;
◆ The product is not suitable for the following places:
1)Places with combustion or explosion hazards;
2)Places with severe vibration or impact;
3)Areas with conductive and chemical gas effects,as well as severe contamination and salt spray.
◇ Please indicate the product name and model;
◇ Please indicate the rated voltage,rated current of the same family of fuse components,and rated breaking current;
◇ Please indicate whether spare partsare required;
◇ Please indicate the order quantity and delivery time.
◇ Please indicate the product name and model;
◇ Please indicate the rated voltage,rated current of the same family of fuse components,and rated breaking current;
◇ Please indicate whether spare partsare required;
◇ Please indicate the order quantity and delivery time.