Factory Price Medium Voltage Drop Out Fuse Cutout for Power System

Drop type fuses and load drop type fuses are outdoor high-voltage protective devices.It is instaled on the high-voltage side of distribution transformers or distribution line branches,used as short-crcuit and overload protection for transformers and lines,as wellas for breaking and closing load currents.The drop type fuse consists of an insulation bracket and a fuse tube.The static contacts are installed at both ends of the insulation bracket,and the dynamic contacts are instlled at both ends of the fuse tube.The fuse tube is composed of an iner arc exinguishing tube and an outer phenolic paper tube or epoxy glasscoth tube.The load drop type fuse enhances the elastic auxiliary contact and arcextinguishing coverto separateand close the load current.
During normal operation of a drop type fuse,the fuse tube forms a closed position bytensioning the fuse.When a system malfunction occurs,the faultcurent causes thefuseto quicky melt,forming an arc extinguishing tube that is heated by the arc and decomposes into a large amount of gas,creating high pressure inside the tube and blowing longitudinaly along thepipeline.The arc is quickly stretched and extinguished.After the fuse melts,the lower moving contact loses tension and fipsdown,locking the mechanism and releasing the fuse tube,causing the fuse tubeto fall and form a clear open position.When it is necessary to pullthe load,use an insulating rod to pul the moving contact.At this time,the active and static auxiiary contacts are stilin contact.Continue touse the insulating rod to pul the contact,and the auxiary contacts are also separated.An arc is generated between the auxiiary contacts,which is elongated in the narow gap of the exinguishing cover.At the same time,the extinguishing cover produces gas.When the curent passes zero,the arcis extinguished.
Availability:
Quantity:
TypeRated
voltage
(kV)
Rated
current
(A)
Breaking
current
(A)
Impulse
voltage
(BIL)
Power-
frequency
withstand
voltage
(kV)
Leakage

distance
 (mm)
Weight
(kg)
Dimensions
  (cm)
Figure

No.
DG-533100100001707066014.566×37×1418
DG-53320012000170706601566×37×1418
DG-6331001000017070660761×42×1319
DG-63320012000170706607.561×42×1319


◆ Environmental temperature:not higher than+40℃ and not lower than -30℃;

◆ Altitude:not exceeding 3000m;

◇ Power frequency:50±2HZ;

◇ Maximum wind speed:35m/s.


This product modelis compiled in accordance with the provisions of JB/T 8321-1996 "Method for Compiling Modelsof AC High Voltage Fuses",as follows:

 7

8

Purpose and Execution Standards

This product is used for branch lines of 10-35kV distribution lines andthe primary side of distribution transformers,for overload and short circuit protection,and for switching the rated load current.

This product model is formulated in accordance with the provisions of JBT8321-1996 "Method for Formulating Models of AC High Voltage Fuses",and the product parameters are executed in accordance with the standard GB/T15166.3-2008 "HighVoltage AC Fuses Part 3:Spray Fuses".