Availability: | |
---|---|
Quantity: | |
1. Insulators are made of high-strength porcelain or imported siicone rubber insulation materials,with excllent insulation performance;
2. The fuse tube adopts an epoxy phenolic glass cloth tube with a fiber lining with a special UV resistant coating,which has excellent UV resistance performance;
3. The rated current of the same family of fuse components is high,up to 200A,and the breaking capacity is strong,up to 16KA.
1. Insulators are made of high-strength porcelain or imported siicone rubber insulation materials,with excllent insulation performance;
2. The fuse tube adopts an epoxy phenolic glass cloth tube with a fiber lining with a special UV resistant coating,which has excellent UV resistance performance;
3. The rated current of the same family of fuse components is high,up to 200A,and the breaking capacity is strong,up to 16KA.
No. | tem | Unit | Technical parameter | ||
1 | Rated frequency | Hz | 50 | ||
2 | Rated voltage | kV | 12 | ||
3 | Rated current of the same family of fuse components | A | 100 | 200 | |
4 | Rated breaking current | kA | 12.5 | 16 | |
5 | Rated short-term power | To ground (dry/wet test) | kV/min | 42/1 | |
Fracture surface (dry/wet test) | 49/1 | ||||
To ground (wet test) | 30/1 | ||||
Fracture surface (wet test) | 36/1 | ||||
6 | Rated lightning impulse | To the ground | kV | 75 | |
Fracture | 85 | ||||
7 | Creepage distance | mm | ≥300(D-level anti fouling) | ||
8 | Mechanical lifespan | Times | 500 |
No. | tem | Unit | Technical parameter | ||
1 | Rated frequency | Hz | 50 | ||
2 | Rated voltage | kV | 12 | ||
3 | Rated current of the same family of fuse components | A | 100 | 200 | |
4 | Rated breaking current | kA | 12.5 | 16 | |
5 | Rated short-term power | To ground (dry/wet test) | kV/min | 42/1 | |
Fracture surface (dry/wet test) | 49/1 | ||||
To ground (wet test) | 30/1 | ||||
Fracture surface (wet test) | 36/1 | ||||
6 | Rated lightning impulse | To the ground | kV | 75 | |
Fracture | 85 | ||||
7 | Creepage distance | mm | ≥300(D-level anti fouling) | ||
8 | Mechanical lifespan | Times | 500 |
1. Altitude:≤1000m.If the altitude is higher than 1000m,the rated insulation level should be adjusted accordingly;
2. Surrounding air temperature:maximum 40℃,minimum -25℃,daily temperature difference of 25K;
3. Humidity:Daily average relative humidity≤95%,monthly average relative humidity ≤90%;
3. Solar radiation intensity:0.1W/cm²;
4. Pollution level:not exceeding level d;
5. Ice thickness:≤10mm;
6. Outdoor wind speed (wind pressure):35m/s(700Pa);
7. Earthquake tolerance(horizontal acceleration):0.3g.
1. Altitude:≤1000m.If the altitude is higher than 1000m,the rated insulation level should be adjusted accordingly;
2. Surrounding air temperature:maximum 40℃,minimum -25℃,daily temperature difference of 25K;
3. Humidity:Daily average relative humidity≤95%,monthly average relative humidity ≤90%;
3. Solar radiation intensity:0.1W/cm²;
4. Pollution level:not exceeding level d;
5. Ice thickness:≤10mm;
6. Outdoor wind speed (wind pressure):35m/s(700Pa);
7. Earthquake tolerance(horizontal acceleration):0.3g.
Ordering Notice
1. Please indicate the product name and model;
2. Please indicate the rated voltage,rated current of the same family of fuse components,and rated breaking current;
3. Please indicate whether spare parts are required;
4.Please indicate the order quantity and delivery time.
Ordering Notice
1. Please indicate the product name and model;
2. Please indicate the rated voltage,rated current of the same family of fuse components,and rated breaking current;
3. Please indicate whether spare parts are required;
4.Please indicate the order quantity and delivery time.