10kV Five-Shed Distribution Type Zinc Oxide Surge Arrester for Power Distribution Systems

The DGG 10kV Distribution Type Metal Oxide Surge Arrester is designed to help protect compatible electrical distribution equipment against transient overvoltages caused by lightning and switching operations.

Featuring a five-shed insulating housing, the product combines a compact external structure with metal terminal connections at both ends.

Its zinc oxide varistor elements provide nonlinear voltage-current characteristics to limit surge voltage and help reduce electrical stress on connected equipment.

The YH5WS series offers different rated voltage configurations, including YH5WS-12.7/50 and YH5WS-17/50, allowing selection according to system grounding conditions and insulation coordination requirements.
Availability:
Quantity:
  • YH5WS

  • DGG

Product Description

10kV Surge Protection for Electrical Distribution Systems

In electrical distribution networks, lightning impulses and switching operations can generate transient overvoltages that affect the insulation performance of connected electrical equipment.

The DGG 10kV Distribution Type Metal Oxide Surge Arrester is developed to help control these overvoltages through the nonlinear characteristics of zinc oxide varistor elements.

Under normal operating conditions, the varistor elements maintain a high-resistance state with relatively low leakage current. When an overvoltage occurs, their resistance decreases rapidly, providing a path for surge current and limiting the voltage across the arrester terminals.

Five-Shed Insulating Structure

One of the visible characteristics of this model is its five-shed external insulating structure.

The shed arrangement forms the external insulation profile of the arrester. The product drawing provides a reference maximum external diameter of 85mm and an insulating body height of 180mm, with an overall height of 260mm.

These structural dimensions can help customers evaluate equipment layout and installation compatibility. Actual creepage distance and insulation performance should be confirmed against the final technical drawing.

Different Rated Voltage Configurations

DGG's 10kV distribution-type product series includes different electrical configurations, such as YH5WS-12.7/50 and YH5WS-17/50.

These models have different rated voltages and continuous operating voltages. Therefore, selecting the correct configuration requires consideration of the actual system voltage, grounding arrangement, temporary overvoltage conditions and insulation coordination.

DGG supports technical specification review and product selection for electrical equipment distributors, engineering contractors and power distribution projects.

Key Features

10kV Distribution Application

Designed for compatible 10kV nominal power distribution system applications.

Five-Shed Insulating Design

Features a five-shed external insulating structure with a defined product profile.

Zinc Oxide Varistor Technology

Uses nonlinear zinc oxide varistor elements to limit transient overvoltages.

Multiple Voltage Configurations

Available in different YH5WS series voltage configurations to meet different system requirements.

Metal Terminal Connections

Upper and lower metal terminals provide connection interfaces according to the installation design.

Compact External Dimensions

The reference drawing specifies an 85mm maximum diameter and 260mm overall height.

Technical Selection Support

Model selection can be reviewed according to Ur, Uc, grounding arrangement and insulation coordination.

Working Principle

The metal oxide surge arrester operates through the nonlinear voltage-current characteristics of zinc oxide varistor elements.

During normal operation, the varistor elements maintain high resistance, allowing only a small leakage current.

When lightning or switching overvoltage occurs, the resistance decreases rapidly, allowing surge current to pass through the arrester and limiting the voltage across its terminals.

After the transient overvoltage subsides, the arrester returns toward its normal high-resistance operating condition.

This process helps protect the insulation of connected electrical equipment against transient overvoltage stress.

Applications

Depending on the selected model and electrical system conditions, this 10kV distribution type surge arrester may be considered for:

  • 10kV-class power distribution networks

  • Distribution transformer protection

  • Medium-voltage switchgear protection

  • Distribution substations

  • Industrial power distribution systems

  • Current transformer protection

  • Voltage transformer protection

  • Capacitor equipment protection

  • Electrical distribution infrastructure

  • Power system insulation coordination

Product Structure

The main visible components include:

  • Five-shed insulating housing

  • Upper metal terminal

  • Lower metal terminal

  • Metal end fittings

  • Threaded connection components

  • Internal zinc oxide varistor elements

Housing material and internal construction should be confirmed according to the detailed production drawing.

FAQ

Q1. What is a 10kV distribution type surge arrester?

It is a metal oxide surge protection device intended for compatible 10kV nominal distribution systems. It helps limit transient overvoltages caused by lightning and switching operations.

Q2. What is the difference between YH5WS-12.7/50 and YH5WS-17/50?

The two models have different rated and continuous operating voltages:

  • YH5WS-12.7/50: Ur 12.7kV, Uc 6.6kV.

  • YH5WS-17/50: Ur 17kV, Uc 13.6kV.

The correct model should be selected according to actual system conditions.

Q3. What does the five-shed design mean?

It refers to the external insulating housing configuration, which features five visible sheds. Actual creepage distance and insulation characteristics should be confirmed using the technical drawing.

Q4. What is the function of a metal oxide surge arrester?

It limits transient overvoltages by using the nonlinear voltage-current characteristics of metal oxide varistor elements.

Q5. Can this arrester be used for transformer protection?

It can be considered for compatible transformer protection applications when its electrical ratings and protective characteristics match the system requirements.

Q6. What information is required for model selection?

Please provide the nominal system voltage, grounding arrangement, required Ur and Uc, temporary overvoltage conditions and installation requirements.

Q7. Can DGG provide technical drawings and test documentation?

Available product drawings, specifications and test documentation can be confirmed according to the selected model and project requirements.

Looking for a 10kV Distribution Type Surge Arrester?

Selecting the right surge arrester requires careful consideration of rated voltage, continuous operating voltage, residual voltage and system grounding conditions.

DGG provides YH5WS series distribution type metal oxide surge arresters for different electrical system requirements.

Send us your technical specifications, equipment drawings or project requirements. Our team can assist with product selection and technical confirmation.

Contact DGG Power for 10kV Surge Arrester Specifications and Quotation.

Previous: 
Next: 
Tel: +86-57757576678
Phone/WhatsApp: +8613706870299

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US NOW!
Copyright    2024  Denggao Electric Co., Ltd.  All Rights Reserved.